30W Single Output Series
|
| |
| |
|
|
 |
|
- AC input range selected by switch
- High reliability
- 100% full load burn-in test
- Protections: overload/ over voltage/ short circuit
- 2 years warranty
- N603 129 x 98 x 40(mm)
|
|
| |
AC input voltage range |
85~132/ 170~264VAC selected by switch |
Input frequency |
47~63Hz |
Inrush current |
cold start, 20A/115V, 40A/230V |
Input leakage current |
0.5mA/ 230VAC |
Line regulation (full load) |
0.5% |
Output voltage adjust range |
10% |
Output overload protection |
110~150% |
Output over voltage protection |
115~150% |
Withstand voltage |
I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min |
Rise time |
50ms@full load (typical) |
Hold up time |
20ms@full load (typical) |
Operating temp. & humidity |
-10 ~+50 , 20%~93%RH (non condensing) |
Storage temp. & humidity |
-20 ~+85 , 20%~95%RH (non condensing) |
Safety standards |
GB4943, UL60950, EN60950 |
EMC standards |
GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 |
Cooling method |
convection |
|
| |
|
| |
Model |
DC Output |
Load regul. |
R&N |
Efficiency |
NO 30W-SF-5 |
5V |
6.0A |
0.5% |
60mV |
72% |
NO 30W-SF-12 |
12V |
2.5A |
0.5% |
80mV |
74% |
NO 30W-SF-15 |
15V |
2.0A |
0.5% |
100mV |
76% |
NO 30W-SF-24 |
24V |
1.3A |
0.5% |
100mV |
78% |
NO 30W-SF-48 |
48V |
0.6A |
0.5% |
150mV |
80% |
* 3~48VDC output all available. |
| |
Note : All Models are also available in 19" Rack Mount. (1u / 2u / 3u), According to customer's specifications. |
| |
|
| |
|