Switching Power Supplies for wireless Application - DC 100, DC 100B/R
|
| |
| |
|
|
 |
|
13.5V, 10 Amps output DC-DC converter suitable for VHF Radio.
DC100 - Input DC range 20 to 30V.
DC100B - Input DC range 40 to 60V.
DC100R - Input DC range 60 to 110V. |
|
| |
|
| |
INPUT SPECIFICATIONS |
|
DC100 |
20 to 30V |
DC100B |
40 to 60V |
DC100R |
60 to 110V |
| |
|
ENVIRONMENTAL |
|
Operating Temperature |
0 - 50°C |
Non-operating Temperature |
0 - 75°C |
Humidity |
5% to 95% Non-condensing |
| |
|
SAFETY & EMI |
|
Safety |
Designed to meet IEC - 1950. |
EMI |
FCC Class - B / CISPR22 |
| |
|
PROTECTIONS |
|
Output Over Voltage |
PSU Trips on over voltage condition. |
Output Over Load end |
Output folds back on over load |
Short Circuit |
Goes to hick-up mode on Short Circuit |
Battery Rev. |
Polarity PSU protected throuh internal fuse |
| |
|
INDICATIONS |
|
Output On |
When output is available |
| |
|
OUTPUT SPECIFICATIONS |
|
AC Input Voltage range |
170 - 270 V AC |
AC Input |
3 Pin 5.0 A Power cord |
DC Output Voltage |
13.5 V DC |
DC Output Current - Equipment |
10.0 Amps |
DC Output Current - Battery* |
5.0 Amps |
Output Ripple ( P-P max )** |
< 1 % |
Output Voltage regulation |
± 3 % |
Batt. deep discharge cut-off facility |
Optional |
Dimensions (W X H X D) |
190 X 75 X 160 (In mm) |
Weight (in Kg.) |
1.9 |
* Battery current when Radio is not in Transmit mode
|
** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output.
|
|
| |
|
| |
|
| |
Note : All Models are also available in 19" Rack Mount. (2u / 3u), According to customer's specifications. |